Functional Description of the Connectors/Interfaces
40
Hardware Description CNC 0610510/12
CNC 61.00
8.2
Pin Assignment and Interfaces
8.2.1
General Information
X
RJ45 - connection with 8-pole female connector
In the following section, the male RJ45 connector and the female connector used for
SIEB & MEYER modules are shown.
For the connection, a shielded and twisted in pairs CAT5 cable of high quality must
be used.
8.2.2
X1 - Connection of Motor Measuring System (Feedback)
X
15-pole female Submin D connector
The shield must be connected to the metal shell of the 15-pole Submin D connector
and, if possible, to the motor connector.
Warning
Wires which are not used must be isolated when fabricating the ca-
ble. Otherwise, a short circuit may occur.
8 7 6 5 4 3 2 1
1 2 3 4 5 6 7 8
Pin
Kabelschirm/
cable shield