7.7
Results
workflow step
7.7.1
Result handling
Result handling consists of methods to define and format device output. Use cases
range from activation of a reject mechanism to output of formatted string results.
Analysis
Overall decision
Digital outputs
Output string
Conditions
Output string expression
Tools
Image
True / False
OK / NOK
Analysis result
Analysis result
Figure 34: Overview of the result handling
Binary results are based on tool tolerances set by the user. Conditions and expressions
can be used for custom result handling without setting tolerances.
7.7.2
Tool result output
Tools return results as values (for example area: 42 mm
2
, angle: 12 degrees) or binary
results (OK/NOK). The binary results are controlled by tolerances set by the user in the
tool parameter pane in the
Task
workflow step, e.g. the number of blobs found by a
Blob
tool. If no tolerances are set, the results will be returned as neutral.
7.7.2.1
Tool result symbols
The overall image result is displayed in the image area. Individual tool results are dis‐
played in the parameter pane in the
Task
workflow step.
Image area
Tool symbol
(parameter
pane)
Tool result
section
(parameter
pane)
Description
Not OK
Result not OK.
OK
Result OK.
Invalid
Result invalid.
OPERATION
7
8021808/12ID/2019-01 | SICK
O P E R A T I N G I N S T R U C T I O N S | TriSpector1000
43