10
Technical data
10.1
Features
Attribute
Value
Tasks
Positioning, inspection, measurement
Technology
3D, line scan, image analysis
Working distance (measured from front win‐
dow)
1008: 56...116 mm range
1030: 141...541 mm range
1060: 291...1091 mm range
Width at minimum working distance
1008: 40 mm
1030: 90 mm
1060: 180 mm
Width at maximum working distance
1008: 75 mm
1030: 330 mm
1060: 660 mm
Maximum height range
1008: 60 mm
1030: 400 mm
1060: 800 mm
Light source
Visible red light (laser, 660 nm)
Laser class
2 (EN/IEC 60825-1:2014)
2M (EN/IEC 60825-1:2007)
Complies with 21 CFR 1040.10 except for
deviations pursuant to Laser Notice No. 50,
dated June 24, 2007
Laser fan angle
45°±2°
Imaging angle
1008/1030: 65°
1060: 67°
Offline support
Emulator
Toolset
Angle, Area, Blob, Distance, Edge, Fix Plane,
Plane, Peak, Point, Shape
10.2
Ambient data
Attribute
Value
Shock load
15 g / 6 ms (EN 60068-2-27)
Vibration load
5 g, 10 Hz...150 Hz (EN 60068-2-6)
Ambient operating temperature
0 °C ... +40 °C (adequate heat dissipation is
required, see
"Mounting instructions", page 16
)
Ambient storage temperature
–20 °C ... +70 °C
Permissable relative air humidity
0% ... 90%, non-condensing
10.3
Interfaces
Attribute
Value
Operator interface
SOPAS
Configuration software
SOPAS
Communication interfaces
Gigabit Ethernet (TCP/IP), serial (RS-232), con‐
figurable digital I/O
Digital inputs
3 x, non-isolated
TECHNICAL DATA
10
8021808/12ID/2019-01 | SICK
O P E R A T I N G I N S T R U C T I O N S | TriSpector1000
61