Access Command
Name
Parameter
Comments
R/W
0x0CE4
Recording trigger
threshold
Range
-2,000,000,000 .
..
+2,000,000,000
Unit: nm
R/W
0x0CE8
Recording start
delay
Range -50,000 ...
+50,000
If positive, start delay; if
negative, number of prelim‐
inary samples
R/W
0x0CF0
Recording control 0x00: Stop
0x01: Start
R
0x0110
File system free
space
Unit: kByte
R
0x0114
File system
capacity
Unit: kByte
R/W
0x0074
Client Port (stor‐
age data)
0 ... 65535
The target IP port for the
data push must be set as a
16-bit signed integer.
R/W
0x0070
Client IP (storage
data)
Byte array
Example: The IP address
192.168.0.200 is the write
parameter 0xC0A800C8
R/W
0x0078
Transmission
interval (storage
data)
0 to 100
Wait time between data
packages in [ms]
R/W
0x0CF8
Storage data
reading
0x00: Stop
0x01: Start
7.4.8
Info
Table 43: Command list for reading information
Cate‐
gory
Command
Name
Parameter
Comments
R
0x0004
Firmware version
R
0x0008
Software version
R
0x0120
Temperature
Unit: 1/1000 °C
R
0x0124
Device operating
time
Unit: s
R
0x0128
Laser operating
time
Unit: s
7.4.9
Determining measured values using time specifications
In addition to the measured values, the associated time specifications are also required
for some operations. Using the following command, the device supplies the measured
values together with a time stamp and then outputs this information.
Table 44: Transmitted command
30
06
00
00
01
F0
00
0C
Table 45: Received command
B0
0C
Measured value
(4 bytes)
Device status/
measurement
result (4 bytes)
Time stamp
(4 bytes)
7
OPERATION
74
O P E R A T I N G I N S T R U C T I O N S | OD5000
8021391/17Y6/2020-05-11 | SICK