7.4.2
Command list
The following commands can be accessed at port 5011 via the UDP interface. The
parameters are always saved as 4-byte values in the big-endian format unless specified
otherwise (with the most significant value in the memory first).
7.4.2.1
Outputting measured values
Table 32: Command list for sensor status and measured values
Access Command
Name
Parameter
Comments
R
0x0D60
Value of channel A dis‐
placement
R
0x0D64
Value of channel B
displacement
R
0x0D68
Value of channel C dis‐
placement
R
0x0D6C
Value of channel D
displacement
R
0x0DA0
Channel A output sta‐
tus
*1
R
0x0DA4
Channel B output sta‐
tus
*1
R
0x0DA8
Channel C output sta‐
tus
*1
R
0x0DAC
Channel D output sta‐
tus
*1
R
0x01F4
Sensor status
*2
Explanation of the bits relating to *1 (status of channel A/B/C/D)
Table 33: Explanation of the bits relating to *1 (status of channel A/B/C/D)
Bit
Comments
1 (0x0001)
Channel switched on/off (corresponding to setting in
0x0200 / 0x0280 / 0x0300 / 0x0380)
2 (0x0002)
Channel output rate (output state)
3 (0x0004)
Measured value of channel valid (0) / invalid (1)
4 (0x0008)
Unused, always 0
5 (0x0010)
Zero teach of channel off (0) / on (1)
6 (0x0020)
Hold function of channel off (0) / on (1)
7 (0x0040)
Unused, always 0
8 (0x0080)
9 (0x0100)
Measured value of channel lower than lower switching thresh‐
old
10 (0x0200)
Measured value of channel between switching thresholds
11 (0x0400)
Measured value of channel higher than upper switching
threshold
12 ... 32
(0x0800 ... 0x80000000)
Unused, always 0