Access Command
Name
Parameter
Comments
R/W
0x0160
User-defined
application tag
30 bytes
7.4.6
Communication
Table 41: Command list for communication settings
Access Command
Name
Parameter
Comments
R
0x0018
MAC address
6 bytes
R/W
0x0CBC
Precision time‐
sync
0x00: OFF
0x01: Slave
0x02: Master
Other communication parameters (IP address, subnet mask...) can only be set via a
web browser (SOPASair).
7.4.7
Saving data
Table 42: Command list for memory settings
Access Command
Name
Parameter
Comments
R
0x0CC4
Recording count
R
0x0CC8
Recording state
0x00: Stopped
0x01: Waiting
0x02: Trigger
standby
0x03: Operating
0x04: Operation
complete
R
0x0CCC
Load
Recording time
Unit: Unix epoch (seconds
since Jan 1, 1970)
R/W
0x0CD0
Recording quota
Range 0 ...
100,000
R/W
0x0CD4
Recording rate
Range 0 ...
100,000
R/W
0x0CD8
Recording repeat‐
ing
0x00: OFF
0x01: ON
W
0x004C
Delete all storage
files
0x024E
R/W
0x0CDC
Recording start
condition
0x00: Immediate
0x01: Alarm Off
edge
0x02: Alarm Off
edge
0x03: Threshold
Up edge
0x04: Threshold
Down edge
0x05: Threshold
Both edge
R/W
0x0CE0
Recording trigger
channel
0x00: Ch.A
0x01: Ch.B
0x02: Ch.C
0x03: Ch.D
OPERATION
7
8021391/17Y6/2020-05-11 | SICK
O P E R A T I N G I N S T R U C T I O N S | OD5000
73
Subject to change without notice