Access
Command
Name
Parameter
Com‐
ments
Channel A Channel B Channel C Channel D
R/W
0x0224
0x02A4
0x0324
0x03A4
Calibration
span
Range
-2,000,00
0 ...
+2,000,00
0
Values
within the
range
-99,999 to
+99,999
are invalid
Applied
factor
multiplied
by
1,000,00
0 (e.g.,
factor 1 →
1,000,00
0)
R/W
0x0228
0x02A8
0x0328
0x03A8
Calibration
shift
Range
-2,000,00
0,000 ...
+2,000,00
0,000
Unit: nm
R/W
0x0230
0x02B0
0x0330
0x03B0
Reference
thickness
Range 0 ...
2,000,000
,000
Unit: nm
Can only
be used
for the
teach
function
when
measur‐
ing thick‐
ness
R/W
0x0234
0x02B4
0x0334
0x03B4
Execute
teach
0x00:
None
0x03:
Teach
thickness
measure‐
ment
0x04:
Reset
teach
thickness
measure‐
ment
0x05:
Teach
upper limit
0x06:
Teach
lower limit
Also used
for teach
for offset
Is
returned
in
response
to read
requests
when
teach is
being exe‐
cuted
R/W
0x0240
0x02C0
0x0340
0x03C0
Output
mode
0x00: DtO
0x01: Win‐
dow
0x02:
ObSB
0x03:
Edge
height
OPERATION
7
8021391/17Y6/2020-05-11 | SICK
O P E R A T I N G I N S T R U C T I O N S | OD5000
71