Function
Meaning
Upper threshold
Memory function starts when measured values exceed the thresh‐
old
Lower threshold
Memory function starts when measured values fall below the
threshold
Both thresholds
Memory function starts when measured values exceed or fall
below the threshold
7.3.12.6
Defining the threshold
The threshold must be defined when one of the following modes is set as the start con‐
dition:
•
Upper threshold
•
Lower threshold
•
Both thresholds
Values of
±
2,000.000 mm are possible; the default value is 0.
7.3.12.7
Defining the trigger channel
The target output is defined in this field when the trigger for the start of the memory
function is defined.
The options are Channel A (default value), B, C, or D.
7.3.12.8
Setting the start position
Indicates by how many measuring points the start of the recording is to be delayed
when the start condition is met.
The following modes are possible:
Table 23: Start position settings
Setting
Meaning
Positive value
Delayed by the specified number of measurements and then
starts the memory function
0
Starts the memory function as soon as the start condition is met
Negative value
Starts the saving function and considers the specified number of
measured values which preceded fulfillment of the start condition
Values of
±
50,000 are possible; the default value is 0.
7.3.12.9
View process
All recorded measurements are listed in this table.
By clicking on the underlined link with the file name of the measurement, the measure‐
ment file can be downloaded in CSV format (values separated by commas).
By clicking in the rows of the corresponding measurement outside of the link, the mea‐
surement process is displayed on the page.
There is a column for the sensor status in the measurement file. It contains a string
with 20 characters and has the following meaning:
LAI- Hiz1 Hiz2 Hiz3 Hiz4L
Table 24: Sensor status
Code
Meaning
L
Laser on
A
Alarm on
7