Access Com‐
mand
Name
Parameter
Comments
R/W
0x0CA8 Synchronization mode
0x00: None
0x01: Synchronous
0x02: Anti-interference 1
0x03: Anti-interference 2
R/W
0x0C10 Sampling rate
0x00: 12.5
0x01: 25
0x02: 50
0x03: 100
0x04: 200
0x05: 500
0x06: 1000
0x09: Auto
0x0A: 14.3
0x0B: 16.7
0x0C: 20
Unit:
μ
s
R/W
0x0C28 Tailoring the measured val‐
ues
0x00: Near
0x01: Center
0x02: Far
Can only be used
when a detection
duration
of 12.5 µs is
selected
R/W
0x0C14 Automated duration of
sampling: Upper limit value
0x01: 25
0x02: 50
0x03: 100
0x04: 200
0x05: 500
0x06: 1000
Can only be used
when automated
detection dura‐
tion is selected
R/W
0x0C18 Automated duration of
sampling: Lower limit value
0x01: 25
0x02: 50
0x03: 100
0x04: 200
0x05: 500
0x06: 1000
Can only be used
when automated
detection dura‐
tion is selected
R/W
0x0C48 Order of sampling
0x00: Near
0x01: Far
R/W
0x0CA4 Measurement direction
0x00: Positive
0x01: Negative
R
0x0400 Waveform
*3
1024 bytes
R
0x0D14 Peak position 1 in wave‐
form
*4
R
0x0D18 Peak position 2 in wave‐
form
*4
R
0x0D1C Peak position 3 in wave‐
form
*4
R
0x0D20 Peak position 4 in wave‐
form
*4
R
0x0D24 Peak position 5 in wave‐
form
*4
R
0x0D28 Peak position 6 in wave‐
form
*4
R
0x0D2C Peak position 7 in wave‐
form
*4
7
OPERATION
66
O P E R A T I N G I N S T R U C T I O N S | OD5000
8021391/17Y6/2020-05-11 | SICK
Subject to change without notice