7
MAINTENANCE AND CARE
90
8011325/18IM/2020-07-02|SICK
O P E R A T I N G I N S T R U C T I O N S | ICR880/890
Subject to change without notice
If the mirror is being replaced, the aligned base support remains in its position on the
mounting frame. Only the unlocked mirror holder, upon which the deflector mirror is
mounted, is removed. It is therefore not necessary to re-adjust the replacement mirror.
1. Unlock the mirror holder. To do this, move the safety arm onto the side over which you
would like to remove the faulty deflector mirror.
Fig. 61: Replacing the deflector mirror (underneath the conveyor) – unlocking the mirror
It is not necessary to unlock both safety arms.
2. Lift the deflector mirror from the base support and remove the mirror from the
mounting frame sideways.
Fig. 62: Replacing the deflector mirror (underneath the conveyor) – removing the mirror
Note