4
MOUNTING
40
8011325/18IM/2020-07-02|SICK
O P E R A T I N G I N S T R U C T I O N S | ICR880/890
Subject to change without notice
Notes on configuration
As a general rule, every unit made up of the illumination unit and the camera is always
mounted together with a deflector mirror. Both the front side of the illumination unit and
the mirror surface must be aligned exactly parallel to each other and at a right angle to
the conveyor system.
Fig. 23: Alignment of the camera system and deflector mirror
No.
Meaning
1
Placement for reading from above/below (view from above)
2
Placement for reading from the side (view from the side)
4.3
Mounting and adjustment
The position of the components on the mounting frame is project-specific and is stated
on a dimensional drawing. During the mounting procedure, the specifications must be
observed as accurately as possible as, to some extent, the values have an influence on
the configuration of the camera system.
Fig. 24: Position of the components of the camera system
No.
Meaning
1
Reference point
2
Distance from the deflector mirror to the reference point
3
Reading point
4
Deflector mirror
5
Distance from the illumination unit and camera to the deflector mirror
6
Illumination unit with camera