COMMISSIONING AND CONFIGURATION
6
67
8011325/18IM/2020-07-02|SICK
Subject to change without notice
O P E R A T I N G I N S T R U C T I O N S | ICR880/890
6.2
Connecting the configuration PC
6.2.1
Establishing a connection with the configuration PC
The camera systems are adjusted to the measuring and reading situation on site using
the SOPAS-ET configuration software. The configuration software is installed on a PC,
which is connected to the controller unit via an Ethernet cable.
Fig. 47: Establishing a connection between the configuration PC and the controller
Connecting the configuration PC
▸
Connect the configuration PC to the controller unit with an Ethernet cable.
It is also possible to establish the connection using an Ethernet switch, to which both
the controller unit and the configuration PC are connected.
Upon delivery, the default IP address for the camera systems is 192.168.0.1.
The IP address is altered during configuration.
▸
Make sure that the configuration PC is in the number range of the controller unit.
▸
If not, change the IP address of the configuration PC accordingly.
Note