MAINTENANCE AND CARE
7
87
8011325/18IM/2020-07-02|SICK
Subject to change without notice
O P E R A T I N G I N S T R U C T I O N S | ICR880/890
Assembling the components of the camera system
1. Remove the yellow protective cap on the new camera (1).
Fig. 56: Camera system replacement – assembling components following component
replacement
2. Attach the camera to the illumination unit on the correct side and carefully insert the
object protection tube into the opening of the illumination unit (2).
3. Fix the screw in the fitting (round hole).
Fig. 57: Camera system replacement – fastening screw in the fitting
4. Screw the camera onto the illumination unit with the four hexagon socket screws
(centering pin with thread).
Aligning the camera system
1. Align the entire unit parallel to the conveying level.
2. Tighten the clamping screws.
Reconnecting the cables
1. Connect the two connection cables of the illumination unit back onto the camera.
2. Connect the two cables coming from an external source back onto the camera.
3. Reconnect the voltage supply.
After initialization of the parameter set saved on the SD memory card, the camera
system adopts this set in the permanent device memory.