ELECTRICAL INSTALLATION
5
49
8011325/18IM/2020-07-02|SICK
Subject to change without notice
O P E R A T I N G I N S T R U C T I O N S | ICR880/890
5.1.3
Connecting several camera systems in line topology
Devices of the ICD890-xxxxxxxS03 variant have three Gbit interfaces. This makes it
possible to connect to the Ethernet network of the controller unit in line topology. An
Ethernet switch is not required for configuration. A HOST ETHERNET interface is no longer
available on these devices.
Fig. 36: Connection principle of several camera systems in line topology
Connection (camera) Function
Connect to
POWER OUT
Voltage supply of the
illumination unit
POWER IN connection of the illumination
unit
ILLUMINATION
Control of the illumination
unit
ILLUMINATION connection of the
illumination unit
POWER IN
DC 24 V
voltage supply
Connection to internal power supply unit of
the controller unit
CAN 1-IN
Internal CAN sensor
network
Connection to CAN bus of the controller
unit or to CAN-OUT of the next camera
system
CAN 1-OUT
Internal CAN sensor
network
Connection to CAN 1-IN of the next camera
system or termination resistor
GBIT 1/3 ETHERNET
Image transmission,
data interface for
configuration
Connection to Ethernet interface of the
controller unit
GBIT 2 ETHERNET
Image transmission
Server for image representation (optional)
Tab. 12: Connection principle of several camera systems (multi-side reading)