Operating Instructions
Chapter
10
CLV 45x Bar Code Scanner
Appendix
8 009 139/K949/06-06-2002
©
SICK AG · Division Auto Ident · Germany · All rights reserved
10-47
5.
Press [RETURN] or [ENTER].
The CLV then interprets all further characters as a new data string.
CLV-Setup sends the character string to the CLV and deletes the entry in the text field.
The CLV does not send an echo.
6.
Once the active reading pulse has ended, the CLV sends the data received from the PC
to the host via the host interface.
Entering a bar code by means of a terminal/PC keyboard
1.
Connect the terminal or PC with terminal emulation to the terminal interface of the CLV
(via AMV/S 40). For pin assignment refer to
Chapter 5.5.6 Connecting the PC,
.
2.
Set the communication parameters and data output format as shown in
3.
Enter the data contents of the bar code on the keyboard.
The terminal sends the individual characters immediately to the CLV.
Use the backspace key to correct input errors.
4.
Terminate the data contents with the control character <CR>.
The CLV then interprets all further characters as a new data string.
The CLV ignores other control characters. The data content itself must not contain any
control characters.
Fig. 10-28: CLV-Setup: Auxiliary input on the terminal emulator
Parameter
Value
Data transfer rate
9 600 bits/s
Data bits
8
ParityNone
Stop bits
1
Data output format
Data terminator
e. g. 1234 CR
Table 10-8: Communication parameters to be set on the terminal/PC for the auxiliary input