Operating Instructions
Chapter
4
CLV 45x Bar Code Scanner
Installation
8 009 139/K949/06-06-2002
©
SICK AG · Division Auto Ident · Germany · All rights reserved
4-3
4.2.6
Mounting accessories
The CLV is fastened by means of two blind hole threads (M 5), which are positioned on the
narrow upper and lower device sides.
shows the position of the thread at the line
scanner.
The complete housing dimensions of the CLV are shown in
and
The CLV can be installed by means of the following SICK retainers:
•
Mounting bracket No. 2 020 410
•
Mounting bracket No. 2 022 564
•
Rod clamp No. 2 023 691
The design of the brackets supports a number of mounting variants and the alignment of
the CLV in two levels.
and
The elongated holes of the mounting bracket No. 2 020 410 make it possible to align the
CLV finely by an angle of rotation of
±
15
°
. The elongated holes of the mounting bracket
No. 2 022 564 and the rod clamp N0. 2 023 691
make it possible to rotate the CLV freely.
Fig. 4-2:
Example of line scanner: Position of the fastening thread at the CLV
10
14.4
4
35.9
13.2
10
4
35.9
Lower side
Upper side
Blind hole thread,
M 5, 5 mm deep
Fig. 4-3:
Line scanner: Example of the mounting possibilities of the CLV with the mounting
bracket No. 2 020 410