Chapter
8
Operating Instructions
CLV 45x Bar Code Scanner
8-14
©
SICK AG · Division Auto Ident · Germany · All rights reserved
8 009 139/K949/06-06-2002
Troubleshooting
8.5.6
Malfunctions: Configuration errors (parameterization)
8.6
SICK Support
If a system error occurs repeatedly (
"CLV SYS failure: xxx", xxx = 000...299
) or if you cannot
correct an error using the above measures, the CLV may be defective. The CLV does not
have any system components whose functionality can be restored by the user after a failure.
Please contact our local SICK office or subsidary:
•
The telephone and fax numbers are listed on the
back page
of this manual.
¾
Do not send the device to the SICK service without first contacting us.
Fault
Possible cause
Remedy
1.
Auto Setup:
The CLV does not read the
presented, application-
specific bar code (no
confirmation from beeper)
•
CLV not in "Auto Setup"
mode
•
If Auto Setup is started with
Profile bar code No. 10:
Wait time of 5 s after power-
up has been exceeded
•
Bar code presented at incor-
rect reading distance
•
Bar code is in total reflection
zone
•
Bar code quality not
adequate
•
Check: Does the "Device
Ready" LED light up? If so,
the CLV is in "Reading" mode
again.
CLV-Setup user interface:
Call up the Auto Setup
function again via the V
IEW
pull-down menu
•
Switch the CLV off and on
again.
Present the Profile bar code
No. 10 within 5 s.
Then the applicationspecific
bar code.
•
Check whether the reading
distance of the bar code lies
within the specified reading
range?
•
Optimize bar code alignment
(scan line should strike the
bar code at a skew of approx.
15 )
•
R
efer to Fault 1
,
2.
Profile programming:
CLV does not read the
presented Profile bar code
(no confirmation by the
beeper)
•
Wait time of 5 s after power-
up has been exceeded
•
Wait time of 10 s after the
first Profile bar code
was presented has been
exceeded
•
In Reading mode: CLV not
pulsed
•
Switch the CLV off and on
again.
Present Profile bar code with-
in 5 s.
•
Once the first Profile bar code
has been read successfully,
present the next bar code
within 10 s, etc.
•
Pulse the CLV accordingly
and present the first Profile
bar code. Present the next
bar code within 10 s, etc.
Table 8-8: Troubleshooting: Configuration errors (parameterization)