Operating Instructions
Chapter
10
CLV 45x Bar Code Scanner
Appendix
8 009 139/K949/06-06-2002
©
SICK AG · Division Auto Ident · Germany · All rights reserved
10-23
1.
Connect the PC to the terminal interface on the CLV using an RS-232 data connection
cable (AMV/S 40: Connect the PC to the internal 9-pin "Service" plug).
(refer to
Chapter 5.5.5 Connecting the CAN interface, Page 5-6
2.
Click on
(AutoBaud detect) in the toolbar or select A
UTO
B
AUD
DETECT
menu item
under the options in the menu bar.
CLV-Setup scans the serial interface by varying the communication parameters and
sends a telegram to the CLV repeatedly. As soon as an answer of the CLV is registered,
CLV-Setup signals the found values of the communication parameters.
shows an example of the event display of the AutoBaud-Detect. CLV-Setup
displays
"Connected"
in the bottom right of the status bar.
3.
Confirm the A
UTO
D
ETECT
dialog box with "OK".
CLV-Setup displays the detected CLV type in a separate dialog box and asks you whe-
ther you want to upload the current parameter record from the CLV.
4.
Confirm the dialog box with "YES“.
CLV-Setup then uploads the current parameter record from the RAM of the CLV to its
database and displays the values on the tab cards.
The current parameter record can be edited in the tab cards.
– or –
2.
Select the S
ERIAL
INTERFACE
menu item under O
PTIONS
in the menu bar.
CLV-Setup displays the current communication parameter settings on the PC in the
COM
PARAMETERS
dialog box.
3.
Ensure that the communication parameters on the PC and CLV are identical
(connec-
ted COM port, 9,600 bits/s, 8 data bits, 1 stop bit, no parity)
4.
Confirm the dialog box with "OK".
CLV-Setup attempts to communicate with the CLV again.
If it is successful, it displays the
"Connected"
status in the bottom right of the status bar.
5.
Click on
in the toolbar.
CLV-Setup uploads the current parameter record from the RAM of the CLV to its data-
base and displays the values on the tab cards.
The current parameter record can be edited in the tab cards.
Fig. 10-18: CLV-Setup: Result display of the AutoBaud-Detect