Chapter
10
Operating Instructions
CLV 45x Bar Code Scanner
10-34
©
SICK AG · Division Auto Ident · Germany · All rights reserved
8 009 139/K949/06-06-2002
Appendix
The online mode of the terminal emulator in CLV-Setup enables the CLV to parameterize
directly with command strings.
contains the view of the terminal emulator with
the command field and output window of the communication between PC and CLV.
1.
Click on
in the toolbar.
The terminal emulator window opens. The CLV is in the Reading mode.
2.
Click on the P
ARAMETERIZE
radio button under D
EVICE
MODE
.
The CLV aborts reading mode. The "Device Ready" LED is extinguished.
CLV-Setup switches the CLV to the Parameterization mode by means of a command.
In the Parameterization mode, all commands begin with the identifier "3".
3.
Enter the desired command in the
➀
command field and press the
[
Return
]
key.
The command is then sent to the CLV.
With a few exceptions, the CLV replies to a command with correct syntax with an echo.
Example:
Entering "3?LT" causes the CLV to output the parameter values of the reading pulse in
encoded form in the output window
➁
.
4.
Click the R
EADING
MODE
radio button to return to the Reading mode.
The "Device Ready" LED lights up.
Note
Changes that are made directly to parameter values in the CLV using command strings are
only registered and displayed in CLV-Setup after the current parameter record has been
uploaded from the CLV.
A list of command strings is available on request
.
Fig. 10-20: CLV-Setup: Entering commands in the terminal emulator
➁