Displaying and editing operating data
This function enables statistical operating data, which the CLV maintains in the form of coun-
ters during the reading procedure, to be sampled and reset.
The CLV does not output a read result in this mode.
1.
Click
in the toolbar.
The CLV aborts reading mode. The "Device Ready" LED is extinguished.
The O
PERATING
DATA
dialog box is opened (
2.
After reading/resetting the desired counters, click on "OK" to confirm the dialog box.
The CLV then returns to the Reading mode and the "Device Ready" LED lights up.
6.5.6
Reading diagnosis
Function of the
terminal interface
. In this mode the CLV outputs the data contents of all the
bar codes that were read - including those that, according to the evaluation criteria, were not
read properly and were thus incorrect - together with the associated reading diagnosis data
via the terminal interface. The number of bar codes output can, therefore, be higher than
the number of those that were sent via the host interface in the read result. In the default
setting this mode is selected for the terminal interface.
shows the corresponding output format of the terminal interface.
In the default setting the CLV does not output any reading diagnosis data via the host.
Should the reading diagnosis be not activated, it can be selected via the A
UXILIARY
INTERFACE
tab card.