10-43
8.
Click on the SW-T
RIGGER
OFF
command button or press [F8].
The CLV confirms that the read was successful by emitting an acoustic signal and then
ends the reading interval. Match code 1 is now stored in the RAM.
9.
Close the switch
to re-energize the "Sensor 2 " switching input.
The CLV saves match code 1 (code type, code length, and data content) permanently
in the parameter record stored in the EEPROM.
Until the supply voltage is switched off it compares whether the bar codes match the
match code 1 in every further reading. It outputs the result state of the comparison via
the "Result 2" output and the "Result" LED with the set pulse length.
10.
Keep the switch closed.
If the switch is opened, the CLV activates the teach-in mode again!
Replacing the match code:
In order to replace the current match code 1 with a new match code using the teach-in me-
thod, simply repeat Steps 5 to 9.
Checking the programmed match code 1 in the CLV:
1.
Switch the supply voltage of the connection module (of the CLV) off and on again.
2.
Carry out an upload from the CLV. To do so, click on
in the toolbar.
3.
The code type and data contents of match code 1 are shown in the C
ODE
COMPARISON
section in the D
EVICE
CONFIGURATION
tab card.
Resetting the reading pulsing to the old state:
1.
Select the D
EVICE
CONFIGURATION
tab card.
2.
Click on the E
DIT
READING
TRIGGER
command button.
3.
Click on the current radio button in M
ODE
in the dialog box.
4.
Carry out the download to the CLV. To do so, click on
in the toolbar.
5.
Confirm the dialog box with the saving option P
ERMANENT
.
The CLV then uses the reading pulse type that was set before the teach-in procedure.
b) Static teach-in procedure
Configuring the static teach-in procedure:
1.
Select the D
EVICE
CONFIGURATION
tab card.
2.
Click on the S
TATIC
WITHOUT
P
HARMACODE
(or S
TATIC
WITH
P
HARMACODE
to read a Pharma-
code) in the T
EACH
-
IN
section.
3.
If necessary, click on the W
ITH
COUNTER
RESET
radio button in the C
OUNTER
RESET
section.
4.
Select the M
ATCH
CODE
TEACH
-
IN
option in the list field in the A
SSIGNMENT
SENSOR
2 section.
5.
If necessary, proceed as follows to activate the output filter in the C
ODE
COMPARISON
sec-
tion:
– Click on the C
ODE
#1
ACTIVE
check box.
– Click on the O
UTPUT
FILTER
check box.
– Click on the C
ODE
#1
ACTIVE
check box again.
The permanent activation of the code comparison is de-activated again. However,
the output filter remains active.
6.
Click on the E
DIT
RESULT
OUTPUTS
command button.
7.
Select the M
ATCH
1 option in the list field in the dialog box under O
UTPUT
FUNCTIONS
for
Result 2 ("Result" LED).