Function
Standard
Advanced
Profes‐
sional
Expert
Programmable monitoring cases in stand-
alone operation
1
4
16
32
Programmable monitoring cases in an EFI
system
32
32
32
32
Static control inputs for monitoring case
switching
–
2
1
1
Static/dynamic control inputs for monitor‐
ing case switching
–
–
2
2
EFI interface (safe SICK device communi‐
cation)
l
l
l
l
Park mode, activation by monitoring case
–
l
l
l
Standby, activation by EFI bit or standby
input
l
l
l
l
Configuration memory in the system plug
l
l
l
l
RS422 data interface
l
l
l
l
Extended CMS features (reflector detec‐
tion, filter function for measured values)
–
–
–
l
1)
Warning field range for a radiance factor of 30% (
see "Characteristic curves", page 128
2)
150 mm resolution configurable only for the Long Range variant with a 3 m scanning range.
3)
Availability depends on the configuration of the universal I/Os (
see "Universal I/O connections",
).
3.2.4
Scanning ranges
The device variants differ with regards to their maximum scanning range and the resul‐
tant protective field size.
1
2
Figure 5: Protective field ranges
1
Medium Range, maximum scanning range 2 m
2
Long Range, maximum scanning range 3 m
3.2.5
Status indicators
The LEDs and 7-segment display signal the operational status of the device. They are
found on the front side of the device.
PRODUCT DESCRIPTION
3
8010948/ZA21/2020-06-18 | SICK
O P E R A T I N G I N S T R U C T I O N S | S300
17