Figure 60: Possible ways of monitoring case switching
1
Local static inputs (S300 Advanced, Professional and Expert)
2
External static inputs via EFI (all S300 variants)
3
Local dynamic inputs (S300 Professional and Expert)
4
Speed information via EFI
•
Indicate and use velocity (S300 Professional and Expert)
•
Use velocity (all S300 variants)
When configuring an EFI system, you define in the CDS the device in which the inputs
are used.
Stand-alone operation
In stand-alone operation of a device, you use the local inputs of the device.
The S300 Advanced has two dual-channel static control inputs A and B.
The S300 Professional and the S300 Expert have three dual-channel control inputs. Of
these control inputs, you can use the inputs A and B as both static control inputs and
also dynamic control inputs.
The dual-channel control input C is formed by the universal I/O 1 and universal I/O 5
connections.
b
Activate the inputs you want to use for monitoring case switching.
If you activate the
Use speed
option, you can use speed ranges for monitoring case
switching.
EFI system
If devices are connected together via EFI, the safety laser scanner can receive control
commands from other devices, e.g., a second safety laser scanner or Flexi Soft safety
controller. For the supported control commands of the safety laser scanner,
.
In an EFI system, you configure which device you want to use for obtaining the input
information.
If the safety laser scanner is connected to a Flexi Soft safety controller, up to five dual-
channel control inputs can be configured.
7
CONFIGURATION
82
O P E R A T I N G I N S T R U C T I O N S | S300
8010948/ZA21/2020-06-18 | SICK
Subject to change without notice