Maximum protective field range
40 mm (hand detection)
1.60 m
50 mm (leg detection)
2.10 m
70 mm (leg detection)
3.00 m
150 mm (body detection)
3.00 m
Complementary information
NOTE
You can configure the warning field up to 8 m for all resolutions. The detection capabil‐
ity within the warning field depends on the radiance factor of the objects to be
detected.
Further topics
•
"Characteristic curves", page 128
7.6.2
Basic response time
The basic response time of the safety laser scanner is 80 ms.
NOTE
You may need to add supplements to the basic response time due to multiple sampling
and data transmission over EFI.
Further topics
•
7.6.3
Maximum protective field range
The maximum protective field range of the safety laser scanner, which depends on the
configured resolution and the variant used, is shown in the CDS.
NOTE
The maximum protective field range of the device must be sufficient to cover the calcu‐
lated protective field size including the necessary supplements.
Further topics
•
•
"Protective field size", page 38
7.7
The S300 Professional and the S300 Expert have two dual-channel dynamic control
inputs using which the possible monitoring cases can be switched depending on the
speed.
Incremental encoders must be connected to the dynamic control inputs for this pur‐
pose. Per incremental encoder, one 0°/90° output is required so that the direction of
travel can be determined.
To use the inputs A and B as dynamic control inputs, select the
Indicate velocity
option.
CONFIGURATION
7
8010948/ZA21/2020-06-18 | SICK
O P E R A T I N G I N S T R U C T I O N S | S300
79