Minimum
Typical
Maximum
At 1 σ
± 28 mm
At 2 σ
± 36 mm
At 3 σ
± 44 mm
At 4 σ
± 52 mm
At 5 σ
± 60 mm
Measurement error on data output via RS-422 (S300 Long Range up to 3 m in the specified
radiance factor range)
Systematic error
± 20 mm
Statistical including systematic error
At 1 σ
± 29 mm
At 2 σ
± 38 mm
At 3 σ
± 47 mm
At 4 σ
± 56 mm
At 5 σ
± 65 mm
Flatness of the scan field at 2 m
± 50 mm
Distance of mirror rotational axis (zero point of X-
and Y-axis) to rear side of device
55 mm
Distance between center point of scan plane and
bottom edge of the housing
116 mm
2)
8 m
Distance measurement range
30 m
Number of multiple samplings (can be configured
via CDS)
2
16
Power-up delay
Configured device
15 s
When the configuration is read out of the system
plug
25 s
Restart after (can be configured)
2 s
60 s
80 ms
1)
Complies with Diamond Grade 3000X™ (approx. 1,250 cd/lx × m²).
2)
The detection capability of the warning field depends on the radiance factor of the objects to be detected
(
see "Characteristic curves", page 128
).
Electric
Table 36: Electric
Minimum
Typical
Maximum
Supply voltage (SELV)
1)
2)
16.8 V
24 V
30 V
Permissible residual ripple
3)
± 5%
Start-up current
4)
2 A
Operating current without output load
5)
0.25 A
0.33 A
Operating current with maximum output load
5)
1.7 A
Power consumption without output load
5)
6 W
8 W
Power consumption with maximum output load
5)
41 W
Power consumption in standby mode or park mode
without output load
5)
6 W
8 W
Electrical connection
System plug with screw connections
TECHNICAL DATA
12
8010948/ZA21/2020-06-18 | SICK
O P E R A T I N G I N S T R U C T I O N S | S300
123