Minimum
Typical
Maximum
Color
RAL 1021 (colza yellow)
Optics cover
Material
Polycarbonate
Interface
Outside with scratch-resistant coating
System plug
ESD-protected
Material
Die-cast aluminum
Color
RAL 9005 (black)
Device dimensions
2)
Height
152 mm
Width
102 mm
Depth
105 mm
Total weight (without connecting cables)
1.2 kg
1)
For detailed information on the safety configuration of the machine/system, please consult your SICK
subsidiary.
2)
Without fixing screws and overrun of cable glands with a mounted system plug.
Functional information
Table 35: Functional information
Minimum
Typical
Maximum
Resolution of the S300 Medium Range
30 mm, 40 mm, 50 mm, 70 mm
Protective field of the S300 Medium Range
At 30 mm resolution
1.25 m
At 40 mm resolution
1.60 m
At 50 mm resolution
2.00 m
At 70 mm resolution
2.00 m
Resolution of the S300 Long Range
30 mm, 40 mm, 50 mm, 70 mm,
150 mm
Protective field of the S300 Long Range
At 30 mm resolution
1.25 m
At 40 mm resolution
1.60 m
At 50 mm resolution
2.10 m
At 70 mm resolution
3.00 m
At 150 mm resolution
3.00 m
Scanning angle
270°
Radiance factor
1.8%
Several
1,000%
(reflectors
1)
)
0.5°
Generally necessary protective field supplement
100 mm
Supplement for retro-reflectors on scan plane with
distance of less than 1 m to protective field bound‐
ary
200 mm
Measurement error on data output via RS-422 (S300 Medium Range up to 2 m in the specified
radiance factor range)
Systematic error
± 20 mm
Statistical including systematic error
12
TECHNICAL DATA
122
O P E R A T I N G I N S T R U C T I O N S | S300
8010948/ZA21/2020-06-18 | SICK
Subject to change without notice