118
11.3 Standard Setting Functions
11.3.1 Standard Setting Functions
Table 11.3.1 Standard Setting Functions
Function
Description
Burnout
When input is burnt out, indication is deflected to the span side. Burnout can
be specified for every channel. (DC voltage of
50 mV max, TC input )
Tag Number
Sets a tag number by up to 7 figures per channel. (Printed at a logging
printing)
Reference Junction
Compensation
Specifies an inside/outside of the Reference Junction Compensation.
Copy Function
Copies a channel setting.
Input offset
Sets the input offset per channel.
Zone Recording
(Track Recording)
Specifies a recording area per channel to separate the record into Tracks.
Partial
Compression/Expansion
Records Partial Compression/Expansion to 1-crease line per channel.
Decade Recording
Indication
Records and indicates by up to 5 decades. 2 digits are effective for indication
and printing.
Alarm Printing
Prints Occurrence time, Occurrence channel, Alarm setting No. and Alarm
type in red when an alarm occurs.
Alarm Recovery Printing
Prints Recovery time, Recovery channel, Setting No. and Alarm type in
purple when alarm recovers.
Recording Start/Stop
Printing
Prints Time and Start/End comment when recording starts and stops.
Synchronous, Asynchronous or OFF can be selected.
Computation
Computes Square root.
Interchannel Computation
Computes Sum, Difference and Average values between channels.
Alarm Hysteresis Width
Sets an alarm hysteresis width to 0% FS or 0.5% FS.
11.4 Optional Functions
11.4.1 Remote Function of DI
Function
Description
Chart Feed Start/Stop
ON: Start, OFF: Stop
Changing Chart feed Speed
ON: 1st, OFF: 2nd
Comment Printing (Sync./Async.)
ON: Comment Printing
Manual Printing (Sync./Async.)
ON: Manual Printing
Date and Time Printing (Sync./Async.)
ON: Date and Time Printing
11.4.2 Alarm Output Function
6 relays
11.4.3 Communication Function
RS-232C (Standard)
RS-485 (Optional)