TECHNICAL MANUAL
ESC ? n
[Name]
Cancel user-defined characters
[Format]
ASCII
ESC
?
n
Hex
1B
3F
n
Decimal 27
63
n
[Range]
32 ≤
n ≤ 126
[Description] Cancels user-defined characters.
[Notes]
This command cancels the pattern defined for the character code
specified by n.
After the user-defined characters is canceled, the corresponding pattern
for the internal character is printed.
This command deletes the pattern defined for the specified code in the
font selected by ESC !.
If a user-defined character has not been defined for the specified
character code, the printer ignores this command.
[Reference]
ESC &, ESC %
ESC @
[Name]
Initialize printer
[Format]
ASCII
ESC
@
Hex
1B
40
Decimal 27
64
[Description]
ESC @ is initializes the printer.
[Notes]
The data in receive buffer is not cleared.
Adjustment amount of the label starting position using
“
GS A
”
command
is not cleared.
ESC D [
n1
...
nk
] NUL
[Name]
Set horizontal tab positions
[Format]
ASCII
ESC
D n1
……
nk NUL
Hex
1B
44 n1
……
nk 00
TITLE : WTP-100
Page35
Decimal 27
68 n1
……
nk 0