TECHNICAL MANUAL
The horizontal and vertical motion unit is specified by
“
GS P
”
.
Changing the horizontal or vertical motion unit does not affect the current
line spacing.
The
“
GS P
”
command can change the horizontal (and vertical) motion
unit.
However, the value cannot be less than the minimum vertical movement
amount, and it must be in even units of the minimum vertical movement
amount.
In standard mode, the vertical motions until (y) is used.
This command function as follows in page mode, depending on the
starting position of the printable area :
When the starting position is set to the upper left or lower right to the
printable area using
“
ESC T
”
, the vertical motion unit (y) is used.
When the starting position is set to the upper right or lower left of the
printable area using ESC T, the horizontal motion unit (x) is used.
The maximum line spacing is 40 inches. When the setting value exceeds
the maximum, it is converted to the maximum automatically.
[Default]
Line space is equivalent to approximately 4.23mm(1/6inch)
[Reference] ESC 2, GS P
ESC = n
[Name]
Set peripheral device
[Format]
ASCII
ESC
=
n
Hex
1B
3D
n
Decimal 27
61
n
[Range]
1≤
n ≤ 255
[Description]
Selects device to which host computer sends data, using n as follows:
[Default] n=1
Bit
Off/On
Hex
Decimal
Function
Off
00
0
Printer disabled
0
On
01
1
Printer enabled
1-7
-
-
-
Undefined
[Notes]
When the printer is disabled, it ignores all data except for error-recovery
commands (DLE EOT,DLE ENQ, DLE DC4) until it is enabled by this
command.