94
Operating Instructions – MOVIGEAR® SNI-B
5
Assignment of optional plug connectors
Electrical installation
Connection cable
The following table provides an overview of the cables available for this connection:
Connection of
cables with open
end
The following table shows the conductor assignment of the cable with the following part
number:
1 174 145 7
Connection cable
Conformity /
part num-
ber
Length/
installation
type
Operating
voltage
CE/UL:
1 174 145 7
Variable
DC 60 V
Open
M23, 12-pole,
0°-coded
Signal name
Color coding
DI01
Pink
DI02
Gray
DI03
Red
DI04
Blue
Reserved
Yellow
Reserved
Green
Reserved
Purple
+24V_O
Black
0V24_O
Brown
0V24_SEN
White
+24 V_SEN
Gray/pink
FE
Red/blue