Operating Instructions – MOVIGEAR® SNI-B
103
6
Description of DIP switches
Startup
6.3
Description of DIP switches
6.3.1
Overview
The following figure shows the DIP switches S1 and S2:
DIP switch S1
The following table shows the functions of DIP switch S1:
DIP switch S2
The following table shows the functions of DIP switch S2:
NOTICE
Damage to the DIP switches caused by using unsuitable tools.
Possible damage to property.
• To set the DIP switches, use only suitable tools, such as a slotted screwdriver with
a blade width of no more than 3 mm.
• The force used for setting the DIP switches must not exceed 5 N.
9007201622737931
ON
DIP
12
3
4
S2
ON
DIP
12
3
4
S1
DIP switch
S1
1
2
3
4
Binary coding SNI unit address
Bit 2
0
Bit 2
1
Bit 2
2
Bit 2
3
ON
1
1
1
1
OFF
0
0
0
0
DIP switch
S2
1
2
3
4
Binary coding operating mode
Use of the
motion control
inputs
Reserved
Bit 2
0
Bit 2
1
ON
1
1
Local mode
res.
OFF
0
0
Sensors
res.
00
I