128
Operating Instructions – MOVIGEAR® SNI-B
8
Overview of power section parameters
Parameters
8.3.2
Parameters that can be changed
Storage location
Setpoints/ramp generators
INFORMATION
The following parameters are stored in the drive unit.
If the drive unit is replaced, for example, in case of ser-
vice, changes made to these parameters must be made
again.
The changes remain active after changing the electronics
cover.
Index
Parameter name
Unit
Meaning / value range
Power section parameters \ setpoints/ramp generators \ setpoint monitoring
Setpoint adjustment
8468.0
Setpoint filter
0.00 – 5.00 – 3000.00 [ms]
1 digit = 0.001 ms
Setpoint stop function
8578.0
Setpoint stop function
•
0 = Off
•
1 = On
8579.0
Stop setpoint
160 – 500 rpm
1 digit = 0.001 rpm
8580.0
Start offset
0 – 30 – 500 [rpm]
1 digit = 0.001 rpm
Power section parameters \ setpoints/ramp generators \ speed ramps
Ramp generator 1
8470.0
Ramp t11 up CW
0.0 – 4.0 – 2000.0 [s]
1 digit = 0.001 s
8471.0
Ramp t11 down CW
0.0 – 4.0 – 2000.0 [s]
1 digit = 0.001 s
8472.0
Ramp t11 up CCW
0.0 – 4.0 – 2000.0 [s]
1 digit = 0.001 s
8473.0
Ramp t11 down CCW
0.0 – 4.0 – 2000.0 [s]
1 digit = 0.001 s
Stop ramps
8476.0
Stop ramp t13
0.0 – 2.0 – 2000.0 [s]
1 digit = 0.001 s
8477.0
Emergency stop ramp t14
0.0 – 2.0 – 2000.0 [s]
1 digit = 0.001 s
Ramp monitoring functions
8928.0
Ramp monitoring
•
0 = Off
•
1 = On
Power section parameters \ setpoints/ramp generators \ fixed setpoints
Fixed internal setpoints
8489.0
Fixed setpoint n11
-2000.0 – 150.0 – 2000.0 [rpm]
1 digit = 0.001 rpm
8490.0
Fixed setpoint n12
-2000.0 – 750.0 – 2000.0 [rpm]
1 digit = 0.001 rpm
8491.0
Fixed setpoint n13
-2000.0 – 1500.0 – 2000.0 [rpm]
1 digit = 0.001 rpm
Drive
unit
Electronics
cover
00
I