Operating Instructions – MOVIGEAR® SNI-B
129
8
Overview of power section parameters
Parameters
Drive data
NOTICE
Damage to the MOVIGEAR
®
drive unit.
Potential damage to property
• Consult SEW-EURODRIVE before you change the torque limit.
Index
Parameter name
MOVITOOLS
®
MotionStudio
Display
(Range / factory setting)
MOVILINK
®
scaling
Power section parameters \ drive data \ motor parameters
Motor operating mode
8574.0
Operating mode (display value)
•
16 = Servo
•
18 = Servo & IPOS
Motor direction of rotation
8537.0
Direction of rotation reversal
•
0 = Off
•
1 = On
Modulation
8827.0
PWM frequency
•
0 = 4 kHz
•
1 = 8 kHz
Power section parameters \ drive data \ monitoring functions
Speed monitoring
8557.0
Speed monitoring
•
0 = Off
•
1 = Motor mode
•
2 = Regenerative mode
•
3 = Motor/regenerative
8558.0
Speed monitoring delay time
0.00 – 1.00 – 10.00 [s]
1 digit = 0.001 s
Power section parameters \ drive data \ limit values
Setpoint limits
8516.0
Minimum speed
0.0 – 200.0 – 2000.0 [rpm]
1 digit = 0.001 rpm
8517.0
Maximum speed
0.0 – 200.0 – 2000.0 [rpm]
1 digit = 0.001 rpm
Drive limits
8518.0
Current limit
In connection with mecha-
tronic MOVIGEAR
®
drive
unit:
0 – 250 – 400 [%I
N
]
1 digit = 0.001 %I
N
In conjunction with DRC
electronic motor:
0 – 250 – 300 [%I
N
]
1 digit = 0.001 %I
N
9951.3
Effective current limit
Only in connection with
mechatronic MOVIGEAR
®
drive unit:
0 – 400 [%I
N
]
1 digit = 0.001 %I
N
8688.0
Torque limit
In connection with mecha-
tronic MOVIGEAR
®
drive
unit:
0 – 250 – 400 [%I
N
]
1 digit = 0.001 %I
N
In conjunction with DRC
electronic motor:
0 – 250 – 300 [%I
N
]
1 digit = 0.001 %I
N
00
I