Operating Instructions – MOVIGEAR® SNI-B
203
12
Technical data
Technical data and dimension sheets
12.1.3 Current carrying capacity of terminals and plug connectors
12.1.4 Motion control inputs
12.1.5 Internal voltage supply 24V_O
Current carrying capacity of terminals and plug connectors
Supply system terminals
X2
24 A (max. loop-through current)
Control terminals
X7
3.5 A (max. loop-through current)
Signal plug connector
X5131
400 mA (max. current for 24 V sensor supply)
Motion control inputs
Input type
DI01 to
DI04
1)
1) Only in conjunction with optional plug connector X5131
PLC-compatible according to EN 61131-2 (digital inputs type 1)
R
i
≈
3.0 k
Ω
, I
E
≈
10 mA, sampling interval 2 ms
Number of inputs
4
Signal level
+15 V to +30 V "1" = Contact closed
–3 V to +5 V "0" = Contact open
Permitted total current
For 4 sensors
400 mA
Internal voltage supply for non-safety-related enable signal via STO input
Voltage supply
+24V_O
DC 24 V to EN 61131-2, interference voltage proof and short circuit proof
0V24_O
Permitted total current
60 mA
Required current for STO-IN sup-
ply
30 mA
P
i
f
kVA
Hz
n