Operating Instructions – MOVIGEAR® SNI-B
153
8
Description of power section parameters
Parameters
Power section parameters \ setpoints/ramp generators \ fixed setpoints
Fixed setpoints
n11, n12, n13
index 8489.0,
8490.0, 8491.0
Use this parameter to set the fixed setpoints n11, n12, n13:
• Setting range: 0 – 2000 rpm
You can activate up to three fixed setpoints (binary coded) using the virtual digital inputs
or process data words.
Programming the input terminals:
Fixed setpoints
Factory setting
Index 8489.0
Internal setpoint n11
n11 = 150 rpm
Index 8490.0
Internal setpoint n12
n12 = 750 rpm
Index 8491.0
Internal setpoint n13
n13 = 1500 rpm
Response
Virtual terminal
n11
n12
Enable/Stop
Stop with t13
x
x
0
Fixed setpoint not active
0
0
1
n11 effective
1
0
1
n12 effective
0
1
1
n13 effective
1
1
1
00