74
Operating Instructions – MOVIGEAR® SNI-B
5
Terminal assignment
Electrical installation
5.4
Terminal assignment
The following figure shows the terminal assignment of MOVIGEAR
®
SNI:
WARNING
Electric shock due to regenerative operation while turning the shaft.
Severe or fatal injuries.
• Secure the output shaft against rotation when the electronics cover is removed.
9007201626438795
Assignment
Terminal
No
.
Name Marking
Function (permitted tightening torque)
X2 line
terminals
–
L1
Brown
Actuator supply phase L1 with SNI communication (1.2 to
1.4 Nm)
–
L2
Black
Actuator supply phase L2 with SNI communication (1.2 to
1.4 Nm)
–
L3
Gray
Actuator supply phase L3 with SNI communication (1.2 to
1.4 Nm)
–
PE
–
Protective earth connection (2.0 to 3.3 Nm )
PE
PE
PE
PE
L1
L2
L3
1
11 12 13 14 15
2
3
4
5
X2
X7
Control terminals
INFORMATION
The communication method requires that you must observe the order of the line
phases L1, L2, L3 between SNI controller and SNI stations 1 to 10.