Plug connectors
Electrical installation
5.9.3
Plug connector positions
The following figure shows possible plug connector positions. A difference is made be-
tween plug connectors with selectable position and plug connectors with fixed position:
Plug connector
Color
Position Position
X5131: Digital inputs/outputs
–
As
required
X, 2 or 3,
not together with X1241_1, X1241_2
X5502: STO
Orange
Fixed
3 (left)
X5503: STO
Orange
Fixed
3 (right)
X1241_1: AC 400 V connection with SNI
1)
1) Plug connector X1241_1 is also available separately (i.e. without plug connector X1241_2).
Red
As
required
X, 2 or 3, not together with X5131
X1241_2: AC 400 V connection with SNI
Red
As
required
X, 2 or 3, not together with X5131
[1] Optional pressure compensation
–
Fixed
Depends on mounting position
18014401178299275
[1]
X5502
X1241_1
X1241_1
X1241_1
X1241_2
X1241_2
X1241_2
X5503
X5131
X5131
X5131
[1]
X
2
3