10
Technical data
Safety technology
Operating Instructions – MOVIPRO
®
PHC2.A-A..M1-E45C-C5
172
10.11
Safety technology
10.11.1 General
Safety characteristics
Approved safety classes of
the device
Performance level d according to EN ISO 13849‑1
Service life
20 years
Safe condition
Frequency inverter does not generate a rotating field. Connected brakes
are de-energized.
Probability of dangerous fail-
ure per hour (PFH value)
0 FIT (fault exclusion)
10.11.2 Interfaces for safe disconnection
X5502
Size
Size 1
Size 2
Performance class
2.2 kW/4.0 kW/7.5 kW
11 kW/15 kW/22 kW
Control voltage range for a
safe state
DC 0 V – 4 V
Maximum permitted residual
current in safe state
DC 6 mA
Control voltage range for a
non-safe state
DC 4 V – 28.8 V
Rated output current
DC 500 mA
Output current limit
Max. DC 2 A (until thermal switch-off)
Power consumption of single
drive
3.7 W
8.7 W
Input capacitance of single
drive (diode-decoupled)
32 µF
275 µF
Power consumption of group
drive
4.9 W
9.9 W
Input capacitance of group
drive (diode-decoupled)
37 µF
280 µF