6
Electrical installation
Electrical connections
Operating Instructions – MOVIPRO
®
PHC2.A-A..M1-E45C-C5
142
6.12.25 X5111: Fan subassembly
Function
Temperature-controlled DC 24 V switching output for additional external fan
Connection type
M12, 5-pin, female, A-coded
Wiring diagram
1
4
3
2
5
No.
Name
Function
1
res.
Reserved
2
res.
Reserved
3
0V24
0V24 reference potential
4
+24V_FAN
DC 24 V output – fan (switching signal)
5
res.
Reserved
Connection component
Fan subassembly
Part number: 12709700
Connection: M12
9007201865010315
26596598/EN – 10/2020