7
Startup
For your safety
Operating Instructions – MOVIPRO
®
PHC2.A-A..M1-E45C-C5
145
7
Startup
7.1
For your safety
NOTICE
Danger due to arcing.
Damage to electrical components.
•
Do not disconnect power connections during operation.
•
Do not connect power connections during operation.
INFORMATION
To ensure fault-free operation, do not disconnect or connect signal cables during
operation.
7.2
Requirements
•
You have installed the device correctly both mechanically and electrically.
•
The system and connected drives must be configured correctly.
•
Safety measures prevent accidental drive startup.
•
Safety measures prevent danger to persons or machines.
•
To prevent unintentional startup of the motor, establish a safe working environ-
ment. Proceed as follows to do so:
– Set the device to a safe state.
– Switch off the output stage.
– De-couple the drive.
– Deactivate auto-reset for drives that start up automatically.