Technical data
Communication and control unit
Operating Instructions – MOVIPRO
®
PHC2.A-A..M1-E45C-C5
171
10.10.2 DC 24 V output
DC 24 V output X2312
Nominal output voltage
DC 24 V
Nominal output current
DC 500 mA
Output current limit
Maximum 1.4 A
10.10.3 Ethernet fieldbus interface
Ethernet fieldbus interface X4233
Transmission rate
10/100 Mbit/s
Properties
Half/full duplex, auto negation, auto crossover
Maximum cable length
100 m according to IEEE 802.3
10.10.4 CAN interfaces
CAN interfaces X4101/X4111
General
According to CAN specification 2.9, parts A and B
Transmission technology according to ISO 11898
A maximum of 64 stations
Baud rate
125 kBaud – 1 MBaud
Maximum cable length
Depends on the baud rate according to CAN specification
Bus termination
X4111
X4101
120 Ohm terminated in the device
No integrated terminating resistor
10.10.5 RS485 interface
RS485 interface X4011
General
I/O standard
Baud rate
2.4 – 115.2 kBaud
Bus termination
The interface is equipped with a dynamic terminating resistor inside the
device.