6
Electrical installation
Electrical connections
Operating Instructions – MOVIPRO
®
PHC2.A-A..M1-E45C-C5
143
6.12.26 X5502: Safe disconnection – input
INFORMATION
To avoid non safety-related shutdown, jumper this connection only if the product will
not perform any safety functions according to EN ISO 13849-1.
INFORMATION
Use only shielded cables for this connection.
This connection is marked with a yellow ring.
Function
Input for safe disconnection
Connection type
M12, 5-pin, female, A-coded
Wiring diagram
1
4
3
2
5
No.
Name
Function
1
+24V
DC 24 V output
2
STO-
0V24 reference potential for safe disconnection
3
0V24
0V24 reference potential
4
STO+
DC 24 V input for safe disconnection
5
res.
Reserved