10
Technical data
DC 24 V backup voltage
Operating Instructions – MOVIPRO
®
PHC2.A-A..M1-E45C-C5
166
10.4
DC 24 V backup voltage
X121.
Nominal input voltage
U
1_N
DC 24 V -15%/+20% (EN 61131-2)
Own consumption
≤ 500 mA (with 24 V)/15 W
Total power consumption
Own consu output current on buses and I/Os
Nominal output voltage
DC 24 V −15%/+20%
corresponds to PELV according to EN 61800-5-1
Nominal output current
DC 3 A
Power limitation at 100 W output power
10.5
Axis data
Size
Size 1
Size 2
Performance class
2.2 kW
4.0 kW
7.5 kW
11 kW
15 kW
22 kW
Axis type PFA
MD022B
MD040B
MD075B
MD110B
MD150B
MD220B
Connection designation
X2012_..
X2016_..
Nominal output power S1 ac-
cording to EN 600341
2.2 kW
4 kW
7.5 kW
11 kW
11 kW,
15 kW with
optional
fan
11 kW,
22 kW with
optional
fan
at PWM frequency = 4 kHz
Nominal output current
AC 5.5 A
AC 9.5 A
AC 16 A
AC 24 A
AC 32 A
AC 46 A
Current limiting
AC 8.25 A
AC
14.25 A
AC 24 A
AC 36 A
AC 48 A
AC 69 A
Motor and regenerative, duration depending on the utilization
Output voltage
3 × AC 0 – 500 V
PWM frequency
Adjustable: 4/8/12/16 kHz
Speed range
- 6000 – 0 – + 6000 min
-1
Resolution
0.2 min
-1
over the entire range
Temperature sensor for single
drive
TF/TH/KTY: When using devices designed for group drive (2 motor con-
nections), the temperature sensor contacts on the motor connection not in
use must be jumpered.
Temperature sensor for group
drive
TH (series connection via both drives)
Maximum motor cable length
30 m
26596598/EN – 10/2020