R..7, F..7, K..7, S..7, Spiroplan
®
W Gear Units – Operating Instructions
Startup
5
Startup
5.1
Startup of helical-worm and Spiroplan
®
W gear units
Running-in
period
Spiroplan
®
and helical-worm gear units require a running-in period of at least 24 hours
before reaching their maximum efficiency. A separate running-in period is required for
each direction of rotation if the gear unit is operated in both directions of rotation. The
table displays the average power reduction during the running-in period.
5.2
Startup of helical, parallel shaft helical and helical-bevel gear units
There are no special startup notes that have to be observed for helical gear units,
parallel shaft helical gear units and helical-bevel gear units, if the gear units have been
mounted according to the section "Mechanical Installation."
Note: The direction of rotation for the output shaft has been changed from CW to CCW
for helical-worm gear units S..7 series compared to the S..2 series. Switch two motor
feeder cables to change the direction of rotation.
No. of
starts
Helical-worm
Spiroplan
®
power reduction
i range
power reduction
i range
1 start
approx. 12%
app. 50...280
approx. 15%
approx. 40...75
2 starts
approx. 6%
app. 20...75
approx. 10%
approx. 20...30
3 starts
approx. 3%
app. 20...90
approx. 8%
approx. 15
4 starts
-
-
approx. 8%
approx. 10
5 starts
approx. 3%
app. 6...25
approx. 5%
approx. 8
6 starts
approx. 2%
app. 7...25
-
-
0
0
I