4
24
R..7, F..7, K..7, S..7, Spiroplan
®
W Gear Units – Operating Instructions
Mechanical Installation
5. Tighten the locking screws by working round several times from one crew to the next
(not diagonally). See table for tightening torques.
Notes on remo-
val of shrink disc
1. Unscrew the locking screws evenly one after the other. To avoid tilting and jamming
of the locking collars, each locking screw may only be unscrewed by about one quar-
ter turn in the initial cycle. Do not fully unscrew the locking screws!
2. Remove the shaft or pull the hub off the shaft (it is necessary to remove any rust
which may have formed between the hub and the end of the shaft).
3. Pull the shrink disc off the hub..
Cleaning and
lubricating the
shrink disc
There is no need to take apart and re-grease disassembled shrink discs before they are
screwed back on.
The shrink disc only needs to be cleaned and re-greased if it is contaminated.
Use one of the following solid lubricants for the tapered surfaces.
Grease the locking screws with a multipurpose grease such as Molykote BR 2 or similar.
01819AXX
Gear unit type
Screw
Nm
max.
1)
1) maximum tightening angle per cycle
FH27
SH37
M5
5
60°
KH37...77
FH37...77
SH47...77
M6
12
KH87/97
FH87/97
SH87/97
M8
30
KH107
FH107
M10
59
KH127/157
FH127
M12
100
Caution!
There is a risk of injuries if the shrink disc is not removed correctly!
Lubricant (Mo S2)
Available as
Molykote 321 (lube coat)
Molykote Spray (powder spray)
Molykote G Rapid
Aemasol MO 19P
AemasolDIO-sétral 57 N (lube coat)
spray
spray
spray or paste
spray or paste
spray
Summary of Contents for F 27 Series