4
26
R..7, F..7, K..7, S..7, Spiroplan
®
W Gear Units – Operating Instructions
Mechanical Installation
IEC adapters
AM250/AM280
1. Clean motor shaft and flange surfaces of motor and adapter.
2. Remove motor shaft key and replace with supplied key (size AM280 only).
3. Heat coupling half (479) (to 80 °C - 100 °C) and slide on motor shaft (A = 139 mm).
4. Fasten coupling half with setscrew and check position (distance "A").
5. Mount motor on adapter; the gearing of the coupling half and the geared adapter
shaft must enmesh.
02047CXX
1 = Motor
shaft
2 =
Setscrew
Note: We recommend applying Noco
®
fluid on the motor shaft prior to installation of the
coupling half to prevent contact corrosion.