4
Mechanical Installation
4.9
Installation of the AM adapter coupling
IEC adapters
AM63 - 225 /
NEMA adapters
AM56 - 365
1. Clean motor shaft and flange surfaces of motor and adapter.
2. IEC adapters: Remove motor shaft key and replace with supplied key (484).
NEMA adapters: Remove motor shaft key, slide spacer tube (491) on motor shaft
and install supplied key (484).
3. Heat coupling half (479) to approx. 80 - 100°C; slide coupling half on motor shaft.
IEC adapters: until rest on motor shaft shoulder.
NEMA adapters: until rest on spacer tube.
4. Secure key and coupling half with setscrew (481) on motor shaft .
5. Mount motor to adapter; the gearing of the coupling half and the geared adapter shaft
must enmesh.
04469AXX
*
=
NEMA adapters only
1 = motor shaft
Note: We recommend applying Noco
®
fluid on the motor shaft prior to installation of the
coupling half to prevent contact corrosion.