CDHD2
Operator Panel (HMI)
35
Actual Current
Code
d 0 0 0 3
Command
Motor Current
Description
Shows the motor current, in amperes.
If the current is a negative value, DP5 is lit.
VarCom
I
Sequence
Select: d0003
Press:
Shift
Display:
0 0 . # # # .
Examples
During motion, values change continuously.
0 0 . 1 7 8 .
0 0 . 1 8 8 .
0 0 . 1 9 2 .
0 0 . 2 0 4 .
Digital Inputs 1 through 10
Code
d 0 0 0 4
Command
Digital Inputs State
Description
Indicates the state of digital inputs 1 through 10.
Double height line = on
Single height line = off
Read from left to right.
VarCom
IN
Sequence
Select: d0004
Press:
Shift
Examples
Digital input 1 on. Digital inputs 2 through 10 off.
Digital input 2 on. Digital inputs 1, 3 through 10 off.
Digital 1 though 10 are all on.
Digital inputs 1 though 10 are all off.