Troubleshooting
CRITICAL_FAULT_ABB_SHUTDOWN
This indicates that the ABB experienced a fault. The response will include four bitmaps: ABB Status, Battery Hazards, Battery
Faults, and Build ID. All four of these bitmaps are packed into the two Data bitmaps in the faultlog. They are arranged as such:
ABB Status
Data[0] High
Battery Hazards Data[0] Low
Battery Faults
Data[1] High
Build ID
Data[1] Low
The following tables provide the bitmaps for ABB Status (Data[0] High) and Battery Hazards (Data[0] Low). If Battery Faults
(Data[1] Low) is anything other than 0x0000, contact Segway to purchase a replacement battery.
The mask for ABB Status Bitmap is 0x1FFF000 on Data[0].
Bit
Name
Description
Action
0x0000
ABB_OK
ABB is operational.
None.
0x0001
BCU_COMM_INIT_TIMEOUT
The ABB was not able to start
communications with the battery BCU.
Check ABB connection to battery.
0x0002
LOW_BATTERY_SOC
The battery State Of Charge is lower
than 5%.
Charge the battery.
0x0004
LOW_BLOCK_VOLTAGE
Battery has detected low block voltage
internally on one of its banks.
Charge the battery. If this error occurs
frequently, replace the battery.
0x0008
BATTERY_IS_HOT
The internal battery temperature is too
high for operation.
Turn off the RMP and let the battery
cool down.
0x0010
BATTERY_IS_COLD
The internal battery temperature is too
low for operation.
Turn off the RMP and warm the
battery up.
0x0020
INTERNAL_BCU_FAULT
Internal Battery Control Unit fault.
Replace the battery.
0x0040
LOW_PACK_VOLTAGE
Battery pack voltage has dropped below
its operating range.
Charge the battery.
0x0080
ABB_OVER_CURRENT
ABB has detected that the current draw
has exceeded the fuse rating for a period
of time.
Reduce external load. Check for
shorts.
0x0100
BCU_LINK_FAILED
Communication between the ABB and
the BCU has failed.
Check the connection between the
ABB and battery.
0x0200
ABB_HIT_INTERNAL_FAULT
The ABB has reached points in the
software it should not.
Report to Segway.
0x0400
ABB_HOST_COMMANDS_
SHUTDOWN
The Host has commanded the ABB to
shutdown.
None. If it was unintentional check the
host code.
0x0800
ABB_GOING_TO_SHUTDOWN
A condition has triggered the ABB to
shutdown.
Check the condition in this bitmap.
0x1000
AC_IS_PRESENT
The ABB has detected that a charger is
connected and charging the battery.
This is informational only.
Table 27: ABB Status Bitmap (Data[0] High)
Summary of Contents for RMP 210 V3
Page 1: ...User Manual Segway Robotics Mobility Platform RMP 210 V3 Robotics...
Page 2: ......
Page 20: ...20 RMP 210 RMP 210...
Page 30: ...30 Powering On Off RMP 210...
Page 34: ...34 Connecting RMP 210...
Page 40: ...40 Maintenance RMP 210...
Page 49: ...49 User Manual Troubleshooting...
Page 50: ...Robotics 24927 00001 aa...