- A/C OPERATING PRESS.
A/C operating pressure threshold allows controlling the headers pressure during the phase of dust removal
in order to control the consumption during a shot and the re-inflation after the shot. This threshold is used
to create header re-inflation faults and no consumption header (see re-inflation fault and Pressostatic filter
cleaning solenoid valve not open fault).
If the arrow is placed on A/C OPERATING PRESS. and if the button is pressed, the following display
appears:
Note: Protected by code! appears if protection is activated.
To adjust the value, use
buttons (in a no active mode protection). To quit and valid, press
button.
Remark: If the threshold is set at 0.00, the pressure will always be regarded as good and therefore the
mini header faults will not be created.
- A/C FALL PRESSURE
The value of A/C fall pressure allows to control the headers pressure during the phase of dust removal in
order to control the consumption during a shot. This value is used to create no consumption a/c header
faults (see pressostatic filter cleaning solenoid valve not open fault).
If the arrow is placed on A/C FALL PRESSURE and if the
button is pressed, the following display
appears:
Note: Protected by code! appears if protection is activated.
To adjust the value, use
buttons (in a no active mode protection). To quit and valid, press
button.
Remark: If the threshold is set at 0.00, the pressure fall will always be detected and therefore the no
consumption a/c header faults will not be created.
Possible adjustment range 0.00 to 6.00 Bars
Possible adjustment range 0.00 to 2.00 Bars
Summary of Contents for SFX+NETWORK
Page 21: ...Technical Data Sheet FI 72 0239 0320E Page 21 108 SIGNALLING...
Page 22: ...Technical Data Sheet FI 72 0239 0320E Page 22 108 CONNECTIONS CONNECTION EXAMPLE...
Page 24: ...Technical Data Sheet FI 72 0239 0320E Page 24 108 CONNECTIONS CONNECTION EXAMPLE...
Page 26: ...Technical Data Sheet FI 72 0239 0320E Page 26 108 CONNECTIONS CONNECTION EXAMPLE...
Page 28: ...Technical Data Sheet FI 72 0239 0320E Page 28 108 CONNECTIONS CONNECTION EXAMPLE...
Page 31: ...Technical Data Sheet FI 72 0239 0320E Page 31 108 CONNECTIONS CONNECTION EXAMPLE...
Page 34: ...Technical Data Sheet FI 72 0239 0320E Page 34 108 CONNECTIONS...
Page 37: ...Technical Data Sheet FI 72 0239 0320E Page 37 108 SFX MODULE POWER CONSUMPTION...
Page 38: ...Technical Data Sheet FI 72 0239 0320E Page 38 108...
Page 85: ...Technical Data Sheet FI 72 0239 0320E Page 85 108...